Here you find the explaination of all our symbols.You also can see the explaination on our family pages and product pages. Just hover over the symbol with the cursor.
Light diode
HIE High pressure discharge lamp, metal halide - elliptical
HIT High pressure discharge lamp, metal halide - tubular
HSE High pressure discharge lamp, sodium vapour - elliptical
HST High pressure discharge lamp, sodium vapour - tubular
Low-pressure discharge lamps (compact fluorescent lamps)
Low-pressure discharge lamps (fluorescent lamps 26 mm)
Low-pressure discharge lamps (fluorescent lamps Ø 16 mm)
LST Low pressure discharge lamp, sodium vapour - elliptical
Optional: Low-pressure discharge lamps (compact fluorescent lamps)
Optional: Low-pressure discharge lamps (fluorescent lamps 16 mm)
Optional: Low-pressure discharge lamps (fluorescent lamps 26 mm)
QT Tungsten halogen lamp - tubular
asymmetric beam
asymmetric beam with indirect downlighting
bare lamp: Luminaire bare lamp without reflector
concentrated beam
concentrated beam with indirect component
concentrated wide beam
concentrated wide beam with indirect component
extreme narrow beam
extreme wide beam
extreme wide beam with indirect component
medium beam
medium beam with indirect uplighting
narrow beam
narrow beam with indirect component
wide beam
wide beam with indirect component
indirect beam: Luminaire with soft ceiling illumination
TYPE II or TYPE III: Optimized for streets and squares
Additional colour temperatures The luminaire is optionally available in additional colour temperatures.
Ball impact resistant As standard: Luminaires have been tested in compliance with EN 12 193 (or DIN VDE 0710) for ball impact resistance
CE certification CE certification indicates the conformity of a product with the applicable EC Directives
easy eXchange The luminaire is available with easy eXchange as standard or as optional components.
Emergency lighting As standard: emergency lighting with independent power supply, tested in line with IEC 61347-2-13.
ENEC European test certificate symbol for luminaires and their electric components. It stands for the observance of European standards governing safety and methods of operation
EX zone 1 Luminaires are permitted for EX zone 1 in line with ATEX Directive 94/9/EC. This covers areas in which an explosive atmosphere may occasionally develop from a mixture of air and combustible gases, vapours or mists. Complies with device protection level Gb.
EX zone 2 Luminaires are permitted for EX zone 2 in line with ATEX Directive 94/9/EC. This covers areas in which an explosive atmosphere usually does not form or may only develop temporarily from a mixture of air and combustible gases, vapours or mists. Complies with device protection level Gc.
EX zone 21 Luminaires are permitted for EX zone 21 in line with ATEX Directive 94/9/EC. This covers areas in which an explosive atmosphere may occasionally develop in the form of a cloud of combustible dust present in the air. Complies with device protection level Db.
EX zone 22 Luminaires are permitted for EX zone 22 in line with ATEX Directive 94/9/EC. This covers areas in which an explosive atmosphere usually does not develop or may only develop temporarily in the form of a cloud of combustible dust present in the air. Complies with device protection level Dc.
Fire resistance D As standard: Luminaires are suitable for premises where there is a fire risk due to dust or fibrous particles
Fire resistance F Recessed luminaires are suitable for direct installation within normal inflammable surfaces.
Focussed Lighting Luminaire with optional lumen package.
Harsh operating conditions As standard: Luminaires are designed for harsh operating conditions
IP20 Luminaire protected against ingress of foreign bodies with a diameter > 12.5 mm
IP40 Luminaire protected against ingress of foreign bodies with a diameter > 1 mm
IP44 Luminaire protected against ingress of foreign bodies with a diameter > 1 mm and splash-proof
IP53 Dust and spray-proof luminaire
IP54 Dust and splash-proof luminaire
IP65 Dust-proof luminaire protected against water jets
IP66 Dust-proof luminaire protected against strong water jets
IP67 Dust-proof luminaire protected against temporary immersion
IP68 Dust-proof luminaire protected against permanent immersion (20m)
IP68 10m Dust-proof luminaire protected against permanent immersion (until 10 m)
IP68 1m Dust-proof luminaire protected against permanent immersion (until 1 m)
IP68 20m Dust-proof luminaire protected against permanent immersion (until 20 m)
IP69K As standard: Dust-proof luminaire protected against hot water used in high pressure cleaning
Listed at the Deutsche Bahn Luminaires are standard at the Deutsche Bahn (German Railway)
LUCON® As standard: Luminaires have a LUCON® luminaire connection system installed
Optional: Ball impact resistant Optional: Luminaires have been tested in compliance with EN 12 193 (or DIN VDE 0710) for ball impact resistance
Optional: Emergency Lighting Optional: emergency lighting with independent power supply, tested in line with IEC 61347-2-13.
Optional: Fire resistance D Optional: Luminaires are suitable for premises where there is a fire risk due to dust or fibrous particles
Optional: IP69K Optional: Dust-proof luminaire protected against hot water used in high pressure cleaning
Optional: LUCON® Optional: Luminaires have a LUCON® luminaire connection system installed
Optional: Protection class II Optional: Protection class II / double insulation: Live parts are equipped with double insulation in addition to the basic insulation.
Parts listed at the Deutsche Bahn This luminaire family contains luminaires certified for the Deutsche Bahn (German railyway company).
Protection class I Protection class I / protective earthing: Protection against electric shock is provided by the basic insulation and connection of all touchable metal parts to the protective earth conductor.
Protection class II As standard: Protection class II / double insulation: Live parts are equipped with double insulation in addition to the basic insulation.
Protection class III Protection class III / protective extra low voltage: Protection against electric shock is based on the use of protective extra low voltage.
VDE German test certificate symbol for luminaires. It stands for the observance of German standards governing safety.
XARA® lighting control The luminaire can be integrated into the lighting control system. The sensor is optional.
RAPDEX The luminaire is available with a RAPDEX driver.
IK02 Glass Luminaire with silicate glass cover tested with an impact energy of 0.2 joules.
IK02 PMMA Luminaire with PMMA cover tested with an impact energy of 0.2 joules.
IK03 PMMA Luminaire with PMMA cover tested with an impact energy of 0.35 joules.
IK04 ESG Luminaire with a toughened safety glass cover tested with an impact energy of 0.5 Joules
IK04 Glass Luminaire with silicate glass cover tested with an impact energy of 0.5 joules.
IK04 PC Luminaire with PC cover tested with an impact energy of 0.5 joules.
IK04 PMMA Luminaire with a PMMA cover tested with an impact energy of 0.5 Joules
IK06 ESG Luminaire with a toughened safety glass cover tested with an impact energy of 1 Joule
IK07 ESG Luminaire with a toughened safety glass cover tested with an impact energy of 2 Joules
IK07 PC Luminaire with a PC cover tested with an impact energy of 2 Joules
IK07 PMMA Luminaire with a PMMA cover tested with an impact energy of 2 Joules
IK08 ESG Luminaire with a toughened safety glass cover tested with an impact energy of 1 Joule
IK08 PC Luminaire with a PC cover tested with an impact energy of 5 Joules
IK08 PMMA Luminaire with a PMMA cover tested with an impact energy of 5 Joules
IK09 ESG Luminaire with a toughened safety glass cover tested with an impact energy of 10 Joules.
IK09 PC Luminaire with a PC cover tested with an impact energy of 10 Joules
IK09 PMMA Luminaire with a PMMA cover tested with an impact energy of 10 Joules
IK10 PC Luminaire with a PC cover tested with an impact energy of 20 Joules
IK10 PMMA Luminaire with a PMMA cover tested with an impact energy of 20 Joules
IK11 PC Luminaire with PC cover tested with an impact energy of 50 joules.
IK11+ PC Luminaire with PC cover tested with an impact energy of 150 J.
IK10+ Luminaire with an extremely impact strengthened material tested with an impact energy of 150 Joules